Dec. 30, 1967
1650 Unit A "Slow Down" alarm light was on.
Push "General Clear" and it went off. Then a
unit A "Read Error" occurre" S.A.21218
T.R.=0, B.R = 152, D.R.=0. Pushed General
Clear and immediately got another Read Error:
S.A.00508 T.R.=0, B.R = 202. Had to
push General Clear 3 times to Clear the Read
ERROR. After ~3sec. a read error occurred
again: S.A. = 20428, T.R. = 2, B.R. = 205, D.R=0
Push Clear again and it cycle for ~5 sec and
stopped : S.S. = 0052, T.R. = 0, B:R. 202, D.R.=0.
Have called D. Poole to look at it.
J Gleason

1720 12/30/67
READ ERRORS:


BAND TRR SECT.
152 172 0 2123 HR
152 172 0 2126 (TA ICE)
152 172 0 2124
202 0 1640 2
202 0 1764
202 0 2003 (TWICE)
207 2 0040
START {152 172 0 1722
AT 0 BEORE {202 172 0 1624
EACH OF THESE. {152 172 0 2135
RANDOM, NON-REPEATABLE ---
THE TEMP. CHANGE BUG?? {HONEYWELL SAYS 71°}
D.W.P.