150
Facsimile
Transcription
Status: Needs Review
Dec. 30, 1967
1650 Unit A "Slow Down" alarm light was on.
Push "General Clear" and it went off. Then a
unit A "Read Error" occurre" S.A.21218
T.R.=0, B.R = 152, D.R.=0. Pushed General
Clear and immediately got another Read Error:
S.A.00508 T.R.=0, B.R = 202. Had to
push General Clear 3 times to Clear the Read
ERROR. After ~3sec. a read error occurred
again: S.A. = 20428, T.R. = 2, B.R. = 205, D.R=0
Push Clear again and it cycle for ~5 sec and
stopped : S.S. = 0052, T.R. = 0, B:R. 202, D.R.=0.
Have called D. Poole to look at it.
J Gleason
1720 12/30/67
READ ERRORS:
BAND | TRR | SECT. | |
---|---|---|---|
| 0 | 2123 | HR |
| 0 | 2126 | (TA ICE) |
| 0 | 2124 | |
202 | 0 | 1640 | 2 |
202 | 0 | 1764 | |
202 | 0 | 2003 | (TWICE) |
207 | 2 | 0040 | |
START { | 0 | 1722 | |
AT 0 BEORE {202 172 | 0 | 1624 | |
EACH OF THESE. { | 0 | 2135 |
THE TEMP. CHANGE BUG?? {HONEYWELL SAYS 71°}
D.W.P.