34
Facsimile
Transcription
1100 5 Oct 67
Found that P2 last on core 1
was not being set when DP was the
only processor running. [Fount?] T2
was weak. Replaced 1609 for T2
P2 last came on.
SRR
1100 5 Oct 67
MTA had bad [Fudud?] pinch roller bearing
Put new pinch roller in.
Did not change any clearances on actuator.
Should work but no way to check
as system was and is down for DSK check out
Randy
1145 5 oct 67
DP is still suffering from 2 bugs
1) A JMS to core 2 seems to cobber
the corresponding location in core 0.
Perhaps the instruction fetch from
core 0 clobbers core 2.
In any case the result is
the contents of the wrd in core 0 and
core 2 are [yelling?] "ore"d together.
2) When the DP is running the
CP hangs. It is always waiting for
a RD RS from core 3. It
appears that this is due either to
Notes and Questions
Nobody has written a note for this page yet
Please sign in to write a note for this page