6

OverviewTranscribeVersionsHelp

Here you can see all page revisions and compare the changes have been made in each revision. Left column shows the page title and transcription in the selected revision, right column shows what have been changed. Unchanged text is highlighted in white, deleted text is highlighted in red, and inserted text is highlighted in green color.

3 revisions
Soazdrmm at Jul 30, 2020 11:20 PM

6

2300 07-JAN-68

TTY1 Doubles Characters
RB[?]

0130 8 Jan. 68
Pt. 3 of instruction test loops at
4041 when 2H is on +15 margins with
about +17V. This is too close
for comfort but how can 6205 margins
affect protect and relocate.
Diagnostic claims a CAM 6000
should have caused mem. prot. interupt
It got interupt but no ILL OP flag.
SRR

6

2300 07-Jan-68
TTY1 Doubles Characters
0130 8 Jan. 68
Pt. 3 of instruction test loops at
4041 when [?] is on +15 margins with
about +17V. This is too close
for comfort but how can 6205 margins
affect protect and relocate.
Diagnostic [checks?] a CAM [?]000
should have caused [mem. prot. ?] interrupt
It got interrupt but no ILL or flag.
ARR